SE305 HELP
Introduction
DataLogger
Real Time Graph
Tabular
Graph
Frequently Asked
Question
Introduction
SE305 is a program for collecting data from thermometer which is connected
with a PC or notebook. One may process these data with graphic or text style
interface. The program is very easy to use via the graphic user interface. The
users do not have to search the function within a lot of menus. The major
functions are all in the main window and they are indicated with large icons.
System Required:
Windows 95/98 or
Windows XP\NT 4.0 or above.
Minimum Hardware Required:
486-100 MHz , 16 MB RAM ;
At least 5 MB byte hard disk space
available to install THERMOLINK software.
Recommended display resolution 800X600 with High Color(16 bit).
Real Time Graph
Menu and Buttons
Option - Setup dialog to set attributions of graph.(You can also double click on the graph.)
Range -
Setup range of Y axis .(When you
find there is nothing in the graph, it could be that the data is out of range,
you can adjust the range to fit the graph)
Print - Sent data to the printer.
Clear
all the data.
Pause - Stop
recording data to graph.
Run - Begin
to record data to graph.
Sampling Rate - Time interval of recording data. If you want to change it, move mouse
cursor to the digit you want to change and click, then input the new sampling
rate, then the change will work immediately.
It will keep 5000 data points, when
data points are more than 5000, latest 100 points will shift out.
Tabular
The Tabular window can be used to record
real time data in a table. The maximum records it keeps only depends on the
available memory and hard disk space available.
Button and Menu
New - Reset all the data.
Open - Retrieve files from the disk.
Save - Save the present data to the disk.
Save As - Save the present data to the disk with a new file name.
Print - Sent data in the present table to the printer.
Pause - Stop data recording.
Run - Start data recording.
Output To Graph -
Sent tabular data to another graph.
Sampling Rate - Time interval between each data recording. If you want to change it,
move mouse cursor to the digit you want to change and click, then input the new
sampling rate, the change will work immediately.
Table :
COLUMN - You can adjust the width of each
column. Put your mouse cursor on the vertical line between two column in top
row, then the cursor will become , click mouse left button and hold , drag to adjust the width.
NO - Record number
DATE - record date.
TIME - record time.
MAIN - value of main window of
thermometer.
UNIT - unit of main window.
SECOND - value of sub-window of
thermometer.
TYPE - thermo couple type.
FUNCTION - HOLD,MAX,MIN,AVG,REL
Frequently Asked Question
1.I had connected thermometer to PC serial port and turned thermometer
power on, but it still show "NO CONNECTION".
Answer: It could be that all serial port are occupied by other
application, close all application , restart your computer and run SE305 again.
2. In TABULAR window , I saved a file. Can I use EXCEL to open this file
?
Answer: If the decimal seperator is comma(,) in
your area, you can not use CSV file, because CSV file use comma to seperate
data, this will be confused.(for example 23,6,C,24.6,C) But you can use TXT files instead, it
use tab to seperate to data(for example:
3.How to uninstall SE305 ?
Answer:Uninstall SE305 by launching the
Add/Remove Programs applet out of the Control Panel, highlighting the SE305,
and clicking on the Add/Remove... push button, then it will remove the SE305
folder and files from your computer.
Graph
You can select "Output To Graph"
from Tabular window to get this graph.
Print
- print
graph.
Option - Setup dialog to set attributions of graph.(You can also double click on the graph.)
Undo Zoom - To undo
th Zoom.
You can Zoom this graph by using mouse:
To Zoom:
1. Press and hold the Shift key.
2. Press the left mouse button and drag
the cursor to select the new extents.
3. Release the mouse button.
To Undo the Zoom:
Press the Alt+U key or click Undo Zoom
button.
(Zooming method is not allowed in Real
Time Graph Window.)
DataLogger
When
you have thermometer connected to PC, select "Load Data" to load
recoreded data from the meter and there will be a progress indicator to show
the loading progress.
if error occurs, just click "Load
Data" again.
After the data was loaded,
the left hand side will show how many data sets were loaded and detail
infomation for each data set (start data, start time, recording rate and record
numbers).
for examples:
It will transfer first data set to grah and tabule on the right hand
side every time after you load recorded data from the thermoter and you can
click at any data set to change the set for graph and tabular.
You can choose a rectangle
area on the graph to zoom in for detail.
The vertical dash line
in the graph will match the
highlight row in the tabular, when one click on an other row in the
tablar, the vertical dash line will move to the corresponding position to match
the time, or when you move the mouse cursor directly on the data point in the
praph, the shape of the cursor will change into a "hand", click this
data point will direct the highlight of row to the corresponding record.
Menu:
Open
: Open an old file .
Save : Save this data set to a file .
Print
Graph : Print graph of this data set.
Print : Print tabular of this data set.
Option - Setup dialog to set attributions of graph.(You can also double click on the graph.)
Load : Load recorded data which were saved in
memory of meter to PC.
: When clicked , graph will zoom and fill
the whole window, then the text of this button will become
"Minimize", click again to the original size.
: At beginning, this button is disabled,
when you drag a rectangle on the graph to zoom in the selected area, this will
enabled the button, then you can click it to set the graph to original grid
scale.
Main
Menu: Click to display the main menu.